home  

Products Overview Products Overview Frequency Converters Frequency Converters Products Overview Frequency Converters DROs Amplifiers power amplifiers power amplifiers power amplifiers

 


DROs 0.1 to 44GHz
Dielectric Resonator Oscillators

 

8.0 - 11.3 GHz
Free Running DROs
specification performance
Parameters
Units
Specifications
Model Number
LO-081-FB
LO-086-FB
LO-090-FB
LO-095-FB
LO-099-FB
LO-105-FB
LO-110-FB
Frequency
GHz
7.981-8.389
8.390-8.819
8.820-9.271
9.272-9.747
9.748-10.250
10.251-10.770
10.771-11.320
RF power
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Frequency pushing
kHz
10
10
10
10
10
10
10
Load pulling (2)
MHz
1.64
1.72
1.88
1.9
2
2.1
2.2
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-94
-93
-93
-92
-92
-92
-91
@100 kHz
dBc/Hz
-119
-118
-118
-117
-117
-117
-116
@1 MHz
dBc/Hz
-144
-143
-143
-142
-142
-142
-141
Frequency stability (4)
MHz
.818
.860
.904
.951
1.000
1.05
1.10
Mechanical tuning
MHz
>+/-6.6
>+/-6.8
>+/-7.2
>+/-7.6
>+/-8.0
>+/-8.4
>+/-9.2
Electrical tuning, min (1)
MHz
2.8
2.9
3.1
3.2
3.4
3.6
3.9
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
4
4
Size
inches
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
Outline PDF
 
11.3 - 16 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-116-FB
LO-122-FB
LO-128-FB
LO-134-FB
LO-141-FB
LO-149-FB
LO-156-FB
Frequency
GHz
11.321-11.900
11.901-12.520
12.521-13.160
13.161-13.830
13.831-14.540
14.541-15.290
15.291-16.070
RF power
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Frequency pushing
kHz
10
10
10
10
10
10
10
Load pulling (2)
MHz
2.32
2.44
2.56
2.7
2.84
2.98
3.14
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-91
-90
-90
-89
-89
-89
-88
@100 kHz
dBc/Hz
-116
-115
-115
-114
-114
-114
-113
@1 MHz
dBc/Hz
-141
-140
-140
-139
-139
-139
-138
Frequency stability (4)
MHz
1.16
1.22
1.28
1.35
1.42
1.49
1.57
Mechanical tuning
MHz
>+/-9.6
>+/-9.8
>+/-10.2
>+/-10.8
>+/-11.4
>+/-12.0
>+/-12.6
Electrical tuning, min (1)
MHz
4.1
4.2
4.3
4.6
4.8
5.1
5.4
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
4
4
Size
inches
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
0.610" x 1.000" x 1.000"
Outline PDF
 

Other Parameters Common to Lucix 8.0 - 16.0 GHz FRDRO
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
dBc
dBc
Voltage V(3)
Current mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/year
-25
-70
5-16
180
-40 to +70
-55 to +85
100
3
+/- 1

Notes:
1. Varactor tuning is included in every unit.
2. Maximum frequency variation for 360° phase change in a 1.5:1 load.
3. Recommended input voltage.
4. Unit equipped with on board regulator.
5. Total frequency variation over entire operating temperature range.
6. Total power variation over entire operating temperature range.

 



 


SALES@LUCIX.COM


DRO Catalog Navigation

Free Running DROs

1 - 2 GHz

2 - 4 GHz

4 - 8 GHz

8 - 16 GHz

16 - 26.5 GHz

26.5 - 44 GHz

Phase Locked DROs
External Reference

1 - 2 GHz

2 - 4 GHz

4 - 8 GHz

8 - 16 GHz

16 - 26.5 GHz

26.5 - 44 GHz

Phase Locked DROs
Internal Reference

1 - 2 GHz

2 - 4 GHz

4 - 8 GHz

8 - 16 GHz

16 - 26.5 GHz

26.5 - 44 GHz








































Design DBA: sales@dbasite.com