home  
 

 

 

DROs 0.1 to 44GHz
Dielectric Resonator Oscillators

2.0 - 2.8 GHz
Free Running DROs
specification performance
Parameters
Units
Specifications
Model Number
LO-020-F4B
LO-021-F4B
LO-022-F4B
LO-023-F4B
LO-024-F4B
LO-026-F4B
LO-027-F4B
 
Frequency
GHz
1.955-2.097
2.098-2.205
2.206-2.318
2.319-2.437
2.438-2.562
2.563-2.693
2.694-2.831
 
RF power
dBm
10
10
10
10
10
10
10
 
Frequency pushing
kHz
409
430
452
476
500
526
553
 
Load pulling (2)
MHz
12-15
12-15
12-15
12-15
12-15
12-15
12-15
 
Phase noise
(1 Hz BW)
 
@10 kHz
dBc/Hz
-106
-105
-105
-104
-104
-104
-103
 
@100 kHz
dBc/Hz
-131
-130
-130
-129
-129
-129
-128
 
@1 MHz
dBc/Hz
-141
-141
-141
-141
-141
-141
-141
 
Frequency stability (4)
MHz
223
237
249
262
275
289
304
 
Mechanical tuning
MHz
>+/-1.637
>+/-1.721
>+/-1.810
>+/-1.902
>+/-2.000
>+/-2.102
>+/-2.210
 
Electrical tuning, min (1)
MHz
.70
.73
.77
.81
.85
.89
.94
 
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
 
Tune voltage center (1)
V
4
4
4
4
4
4
4
 
Size
inches
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
 
Outline PDF
 
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
 
2.8 - 4 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-029-F4B
LO-030-F4B
LO-032-F4B
LO-033-F4B
LO-035-F4B
LO-037-F4B
LO-039-F4B
 
Frequency
GHz
2.832-2.976
2.977-3.129
3.130-3.290
3.291-3.458
3.459-3.636
3.637-3.822
3.823-4.018
 
RF power
dBm
10
10
10
10
10
10
10
 
Frequency pushing
kHz
581
611
642
675
710
746
784
 
Load pulling (2)
MHz
12-15
12-15
12-15
12-15
12-15
12-15
12-15
 
Phase noise
(1 Hz BW)
 
@10 kHz
dBc/Hz
-103
-102
-102
-101
-101
-101
-100
 
@100 kHz
dBc/Hz
-128
-127
-127
-126
-126
-126
-125
 
@1 MHz
dBc/Hz
-141
-141
-141
-141
-141
-141
-141
 
Frequency stability (4)
MHz
319336
353
371
390
405
426
216
 
Mechanical tuning
MHz
>+/-2.323
>+/-2.442
>+/-2.568
>+/-2.700
>+/-2.838
>+/-2.984
>+/-3.136
 
Electrical tuning, min (1)
MHz
.99
1.04
1.09
1.15
1.21
1.27
1.33
 
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
 
Tune voltage center (1)
V
4
4
4
4
4
4
4
 
Size
inches
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
0.993" x 1.608" x 0.612"
 
Outline PDF
 
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
4AD001-1
 

Other Parameters Common to Lucix 1- 1.5 GHz and 1.5 - 2 GHz FRDRO
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
dBc
dBc
Voltage V(3)
Current mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/year
                 

Notes: Varactor tuning is included in every unit.
Maximum frequency variation for 360 o phase change in a 1.5:1 load.
Recommended input voltage.
Unit equipped with on board regulator.
Total frequency variation over entire operating temperature range.
Total power variation over entire operating temperature range.