DROs 0.1 to 44GHz
Dielectric Resonator Oscillators
|
|
|
26.5 - 33.9 GHz
Phase Locked DROs - Internal Reference
specification performance
| Parameters |
Units |
Specifications |
Model Number |
|
LO-271-XD |
LO-285-XD |
LO-299-XD |
LO-315-XD |
LO-330-XD |
Frequency |
GHz |
26.501-27.840 |
27.841-29.250 |
29.251-30.730 |
30.731-32.290 |
32.291-33.920 |
RF power (1) |
dBm |
7-10 |
7-10 |
7-10 |
7-10 |
6-9 |
Phase noise |
(1 Hz BW) |
|
@100 Hz |
dBc/Hz |
-65 |
-65 |
-64 |
-64 |
-64 |
@1 kHz |
dBc/Hz |
-90 |
-90 |
-89 |
-89 |
-89 |
@10 kHz |
dBc/Hz |
-100 |
-100 |
-99 |
-99 |
-99 |
@100 kHz |
dBc/Hz |
-108 |
-108 |
-107 |
-107 |
-107 |
@1 MHz |
dBc/Hz |
-133 |
-133 |
-132 |
-132 |
-132 |
Size |
inches |
|
|
|
|
|
Outline PDF |
|
|
|
|
|
|

33.9 - 44 GHz
Phase Locked DROs - Internal Reference
| Parameters |
Units |
Specifications |
Model Number |
|
LO-347-XD |
LO-365-XD |
LO-383-XD |
LO-403-XD |
LO-423-XD |
Frequency |
GHz |
33.921-35.640 |
35.641-37.440 |
37.441-39.340 |
39.341-41.330 |
41.331-43.420 |
RF power (1) |
dBm |
6-9 |
6-9 |
6-9 |
6-9 |
6-9 |
Phase noise |
(1 Hz BW) |
|
@100 Hz |
dBc/Hz |
-63 |
-63 |
-62 |
-62 |
-61 |
@1 kHz |
dBc/Hz |
88 |
-88 |
-87 |
-87 |
-86 |
@10 kHz |
dBc/Hz |
-98 |
-98 |
-97 |
-97 |
-96 |
@100 kHz |
dBc/Hz |
-106 |
-106 |
-105 |
-105 |
-104 |
@1 MHz |
dBc/Hz |
-131 |
-131 |
130 |
-130 |
-129 |
Size |
inches |
|
|
|
|
|
Outline PDF |
|
|
|
|
|
|
Other Parameters Common to Lucix 26.5 - 44 GHz GHz PLDRO-IR
Harmonics |
Spurious |
Supply |
Temperature |
Stability Over Temperature (p-p) |
Aging |
Reference Tuning |
dBc |
dBc |
Voltage V(3) |
Current mA |
Warm-up mA |
Operating °C |
Storage °C |
Frequency ppm (4) |
Power dB (5) |
ppm/10year |
ppm |
-25 |
-80 |
11.4-12.6 |
400 |
545 |
-40 to +70 |
-55 to +85 |
+/- 500 |
3 |
+/- 2 |
+/- 2.5 |
Notes:
1. The [output frequency/(reference frequency)] must be an integer. The integer value N determines the phase noise at <100kHz offsets.
2. The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
3. Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
4. Total power variation over entire operating temperature range.
5. Higher output power is available. Please contact the factory for more information.
6. Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
7. Rugged Ultra Reliable DRO products measure 2.350" x 2.000" x 0.700". |
|
|
|