home  
 

 

 

DROs 0.1 to 44GHz
Dielectric Resonator Oscillators

 

Phased Locked DRO-Internal Reference
16.0 - 20.6 GHz
Phase Locked DROs - Internal Reference
specification performance
Parameters
Units
Specifications
Model Number
line
LO-164-XC
LO-173-XC
LO-182-XFC
LO-191-XC
LO-201-XC
Frequency
GHz
16.071-16.900
16.901-17.760
17.761-18.670
18.671-19.630
19.631-20.640
RF power (1)
dBm
13-16
13-16
13-16
13-16
13-16
Phase noise
(1 Hz BW)
@100 Hz
dBc/Hz
-70
-69
-69
-68
-68
@1 kHz
dBc/Hz
-95
-94
-94
-93
-93
@10 kHz
dBc/Hz
-105
-104
-104
-103
-103
@100 kHz
dBc/Hz
-113
-112
-112
-111
-111
@1 MHz
dBc/Hz
-138
-137
-137
-136
-136
Size
inches
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
Outline PDF
 
lineline
20.6 - 26.5 GHz
Phase Locked DROs - Internal Reference
Parameters
Units
Specifications
Model Number
line
LO-211-XC
LO-222-XC
LO-233-XC
LO-245-XC
LO-258-XC
Frequency
GHz
20.641-21.700
21.701-22.810
22.811-23.980
23.981-25.210
25.211-26.500
RF power (1)
dBm
13-16
13-16
13-16
7-10
7-10
Phase noise
(1 Hz BW)
@100 Hz
dBc/Hz
-67
-67
-67
-66
-66
@1 kHz
dBc/Hz
-92
-92
-92
-91
-91
@10 kHz
dBc/Hz
-102
-102
-102
-101
-101
@100 kHz
dBc/Hz
-110
-110
-110
-109
-109
@1 MHz
dBc/Hz
-135
-135
-135
-134
-134
Size
inches
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
2" x 1.500" x 1.125"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
Outline PDF
 
line

Other Parameters Common to Lucix 16 - 26.5 GHz GHz PLDRO-IR
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
Reference Tuning
dBc
dBc
Voltage V(3)
Current mA
Warm-up mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/10year
ppm
-45
-80
11.4-12.6
400
545
-40 to +70
-55 to +85
+/- 500
3
+/- 2
+/- 2.5

Notes:
1. The [output frequency/(reference frequency)] must be an integer. The integer value N determines
the phase noise at <100kHz offsets.
2. The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
3. Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
4. Total power variation over entire operating temperature range.
5. Higher output power is available. Please contact the factory for more information.
6. Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
7. Rugged Ultra Reliable DRO products measure 2.350" x 2.000" x 0.700".