home  
 

 

 

DROs 0.1 to 44GHz
Dielectric Resonator Oscillators

 

Phased Locked DRO-Internal Reference
1.0 - 1.4 GHz
Phase Locked DROs - Internal Reference
specification performance
Parameters
Units
Specifications
Model Number
line
LO-0102-X8B
LO-0107-X8B
LO-0113-X8B
LO-0118-X8B
LO-0125-X8B
LO-0131-X8B
LO-0138-X8B
Frequency
GHz
.998-1.049
1.050-1.102
1.103-1.159
1.160-1.218
1.219-1.281
1.282-1.347
1.348-1.416
RF power (1)
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Phase noise
(1 Hz BW)
@100 Hz
dBc/Hz
-94
-93
-93
-92
-92
-92
-91
@1 kHz
dBc/Hz
-119
-118
-118
-117
-117
-117
-116
@10 kHz
dBc/Hz
-129
-128
-128
-127
-127
-127
-126
@100 kHz
dBc/Hz
-140
-139
-139
-138
-138
-138
-137
@1 MHz
dBc/Hz
-144
-144
-144
-144
-144
-144
-144
Size
inches
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
Outline PDF
 
lineline
1.4 - 2.0 GHz
Phase Locked DROs - Internal Reference
Parameters
Units
Specifications
Model Number
line
LO-0145-X8B
LO-0152-X8B
LO-0160-X8B
LO-0168-X8B
LO-0177-X8B
LO-0186-X8B
LO-0196-X8B
Frequency
GHz
1.417-1.488
1.489-1.565
1.566-1.645
1.646-1.729
1.730-1.818
1.819-1.911
1.912-2.009
RF power (1)
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Phase noise
(1 Hz BW)
@100 Hz
dBc/Hz
-91
-90
-90
-89
-89
-89
-88
@1 kHz
dBc/Hz
-116
-115
-115
-114
-114
-114
-113
@10 kHz
dBc/Hz
-126
-125
-125
-124
-124
-124
-123
@100 kHz
dBc/Hz
-137
-136
-136
-135
-135
-135
-134
@1 MHz
dBc/Hz
-144
-144
-144
-144
-144
-144
-144
Size
inches
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
2" x 1.883" x 1.280"
Outline PDF
 
line


Other Parameters Common to Lucix 1.0- 2.0 GHz GHz PLDRO-IR
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
Reference Tuning
dBc
dBc
Voltage V(3)
Current mA
Warm-up mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/10year
ppm
-25
-70
11.4-12.6
525
670
-40 to +70
-55 to +85
+/- 500
3
+/- 2
+/- 2.5


Notes:
1. The [output frequency/(reference frequency)] must be an integer. The integer value N determines
the phase noise at <100kHz offsets.
2. The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
3. Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
4. Total power variation over entire operating temperature range.
5. Higher output power is available. Please contact the factory for more information.
6. Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
7. Rugged Ultra Reliable DRO products measure 2.350" x 2.000" x 0.700".